Bearing Grease Quantity and Relubrication Interval Calculator

Plan a rolling-bearing grease charge and service interval with every quantity, assumption, and correction factor visible for engineering review.

Use at your own risk. Confirm dosing and intervals with the bearing and grease manufacturers.

Operating inputs

mm
mm

greater than d

Rheologylab
mm
rpm

Use only a published factor matching the design.

°C

Sustained operating temperature

Stle
—
h/day
g/cm³
cm³

measured, or 0

%

Grease plan

Initial planned charge84.3g
Corrected interval99 h
Replenishment/event10.0 g
Average daily feed0.81 g/day
Base interval778 h

Applied factors:FT 0.397 · FL 0.80 · FO 1.00 · FC 0.50 · FD 0.80

Planning estimate only. Confirm final quantity and interval against bearing and grease manufacturer instructions.

FunctionalProduct
How to use
  1. Confirm the bearing is grease-lubricated and not sealed for life; obtain bore d, outside diameter D, and width B in mm.
  2. Enter maximum continuous speed in rpm, select a published Kf matching the bearing design, and enter sustained grease temperature.
  3. Enter positive P/C; select orientation, contamination control, and operating pattern.
  4. Enter operating hours/day. Include housing grease only from measured free volume, density, and approved fill percent; use zero volume when unknown.
  5. Select Calculate to update the result. Select Reset to restore the worked example.
  6. Read initial charge and corrected interval first, then review replenishment, daily feed, base interval, and all factors.
  7. Correct red input warnings. Treat yellow warnings as a requirement for OEM, bearing, or grease-supplier review.
  8. Do not use for sealed-for-life bearings, oil/solid lubrication, blocked purge paths, lubricator pressure sizing, or safety-critical dosing.
Equations used

dm = (d + D)/2

Gp = 0.005DB

Gh = ρVhφ/100; Ginitial = Gp + Gh

tb = Kf[14,000,000/(n√dm) − 4dm]

Bruker

FT = 1 for T ≤ 70 °C; otherwise 2−((T−70)/15)

FL = 1.0, 0.8, 0.6, or 0.4 for P/C bands ≤0.05, ≤0.10, ≤0.15, or above 0.15.

FO = 1.0 horizontal or 0.5 vertical; FC = 1.0 clean, 0.5 moderate, or 0.25 severe; FD = 1.0 continuous or 0.8 intermittent.

tc = tbFTFLFOFCFD; qh = Gp/tc; qday = qhhop

Operating time hop is the entered operating hours per day, in h/day. It is not an additional correction factor: multiplying the average hourly feed qh (g/h) by hop gives the daily feed qday (g/day).

Lengths are mm, speed is rpm, intervals are hours, and grease mass is g. Kf, factors, and P/C are dimensionless. Load is a positive magnitude; no force sign convention applies. The base interval must be positive. The 0.005DB relation estimates replenishment, not cavity volume.

Worked example

Reset restores d = 50 mm, D = 100 mm, B = 20 mm, n = 1500 rpm, Kf = 1, T = 90 °C and P/C = 0.08. With a horizontal shaft, moderate contamination, intermittent operation and 8 h/day, the base interval is about 778 h and the corrected interval is about 99 h. Replenishment is 10 g/event and average feed is about 0.81 g/day. Housing volume 250 cm³, density 0.90 g/cm³ and fill 33% add 74.25 g, giving an initial planned charge of 84.25 g. Review each correction and the available purge path with the supplier.

Assumptions, limits, and references

Assumes a conventional grease-lubricated rolling bearing, compatible top-up grease, a usable purge path, and operation within grease and bearing limits. Transparent load, orientation, contamination, and duty factors are conservative planning screens rather than a standard or product approval.

Confirm free space, cage design, speed, temperature, load, grease compatibility, and interval with the OEM and grease supplier. High temperature, high speed, vibration, water, aggressive contamination, or unusual geometry requires product-specific review and field adjustment.

References: SKF bearing lubrication guidance; SKF Lubrication Planner; Timken Grease Lubrication Calculator; and Noria lubrication calculators.

Input definitions

Bearing bore d
Nominal bearing bore diameter. Unit: mm.
Outside diameter D
Nominal bearing outside diameter; must exceed d. Unit: mm.
Bearing width B
Nominal bearing width used by the replenishment equation. Unit: mm.
Rotational speed n
Maximum continuous operating speed. Unit: rpm.
Bearing factor Kf
Published bearing-type factor used by the generic interval correlation; select only a factor appropriate to the bearing design. Unit: dimensionless.
Operating temperature T
Highest sustained bearing grease temperature. Unit: °C.
Equivalent load ratio P/C
Equivalent dynamic bearing load divided by basic dynamic load rating. Unit: dimensionless.
Shaft orientation
Horizontal or vertical shaft orientation. Unit: category.
Contamination control
Clean, moderate, or severe contamination/sealing condition. Unit: category.
Operating pattern
Continuous/stable or intermittent/start-stop service. Unit: category.
Operating hours per day
Daily running time used to express an average daily grease feed. Unit: h/day.
Grease density ρ
Grease density used only for optional housing free-space charge. Unit: g/cm³.
Housing free volume Vh
Optional measured housing free volume outside the bearing; enter zero when unknown. Unit: cm³.
Housing fill fraction φ
Fraction of measured housing free volume assigned to grease. Unit: %.